Sign In | Join Free | My himfr.com
Home > Coal Fired Steam Boiler >

Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection

    Buy cheap Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection from wholesalers
     
    Buy cheap Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection from wholesalers
    • Buy cheap Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection from wholesalers
    • Buy cheap Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection from wholesalers

    Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection

    Ask Lasest Price
    Brand Name : YONGXING
    Model Number : DZL/SZL
    Certification : ISO9001,ISO14001,SGS,BV
    Price : negotiable
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : USD1000/SET
    Delivery Time : 10-15days
    • Product Details
    • Company Profile

    Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection

    Horizontal and low pressure SZL double-drum coal/biomass/wood chips steam boiler for garment and laundry


    Features
    1. Original mode water wall structure. Compared with the traditional structure, this structure has the characteristics of large heat transfer area, good conduction effect, low heat loss, good air tightness, no deformation of the furnace wall, and no ash leakage.


    2. Extended grate design. The front and rear shafts of the grate are lengthened, so that the fuel can be more fully burned, and the effective area of ​​the grate is increased, and the boiler has a strong overload operation capability.


    3. Strong adjustment performance. The boiler adopts segmental air supply and has good sealing performance, which can effectively control the air supply volume in each combustion stage and achieve the best adjustment of combustion effect.


    4. High thermal efficiency. The company uses a tube wall and a cast iron economizer to further reduce the temperature of the exhaust and improve the efficiency of heat utilization.


    5. The overall assembly and delivery of the factory saves the user's installation time, reduces the installation cost of the user, and improves the efficiency of the boiler.


    6. The boiler adopts aluminum silicate and centrifugal glass wool as insulation materials, which have good heat preservation performance, light weight and convenient transportation and installation.


    7. The upper part of the boiler is equipped with a fire-catching hole device, and the lower part is provided with a cleaning device for easy maintenance and maintenance.


    8. The manufacture and design of this series of boilers are carried out in accordance with the requirements of GB/T16508.4-2013 "Boiler Shell Boiler Part 4: Manufacturing, Inspection and Acceptance", which fully complies with the national standard.


    Data sheet 1

    Auxiliary components
    Auxiliary SystemParts
    Water supply systemsoft water, demineralized water system, deaerator, feed water pump, water tank, ammonia adding device, dosing device
    Steam (hot water) systemSteam separator (water) cylinder, desuperheater
    Fuel supply systemCoal machine, belt coal conveyor, crusher, vibrating screen electronic belt scale, electromagnetic iron remover, double pear type unloader, pre-furnace coal feeder, etc
    Smoke systemBlower, induced draft fan, chimney, etc.
    Sewage (steam) system, row, row, sampler, silencer
    Electronic control systemGeneral control, PLC control, DCS control
    Other equipment in the boiler roomHeat exchange station, circulation pump, decontamination unit, etc.
    Flue gas purification systemDust collector, desulfurization device, denitration device, etc.


    General standard

    1. Atmospheric pressure boiler paint, packaging should comply with JB/T1615-1991 "boiler paint and packaging technical conditions" provisions.
    2. The water quality of atmospheric boiler feed water and pot water should meet the requirements of GB1576-2001 Industrial Boiler Water Quality.
    3. Pipeline installation shall comply with GB50235-97 "Construction and Acceptance Specifications for Industrial Pipework (Metal Pipeline)" and GBJ242 "Warm Heating
    And Sanitary Engineering Construction and Acceptance Specifications".
    4. No valves shall be installed on the atmosphere communicating pipe and between it and the boiler.
    5. Boiler smoke and dust emissions shall comply with the provisions of GB13271-2001 "Boiler Air Pollutant Emission Standards".
    6. The boiler noise shall comply with the provisions of GB12348-1990 Noise Standards for Industrial Enterprises.


    Data sheet 2

    NO.ParamentsUnitTechnical Data
    1ModelSZL6-1.25-AIISZL6-1.6-AIISZL10-1.6-AIISZL10-2.45-AIISZL10-2.45/400-AII
    2Transportation Sizem9.3×2.6×3.69.3×2.6×3.612.5×2.7×3.96.8×2.6×3.57.9×3.2×3.5
    3Rated evaporation capacityt/h66101010
    4Working PressureMpa1.251.61.62.52.45
    5Steam Temperature183203203280400
    6Thermal Efficiency%75.4476.7375.6576.7378.51
    7Consumpkg/h1002.21188.41389.81412.61914.55
    8Heating Area38.29249.06386.22394.37408.78
    9Grate Area6.68.310.211.7312.8
    10Burning TypeLayer BurningLayer BurningLayer BurningLayer BurningLayer Burning
    11FuelBiomassBiomassBiomassBiomassBiomass
    12WeightT33.636.648.151.752.2

    Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protectionuctions

    Fault diagnosis and processing system features
    1. Steam pressure over-limit protection: When the steam in the pot is over-pressure, the control system immediately enters the equipment to stop working, and the sound and light alarm is given. The screen displays “Vapor pressure is extremely high”. Until the fault is eliminated, press the reset button to cancel the alarm state.


    2. Water shortage protection: When the boiler has a low water level failure due to pump failure or other reasons, the control system immediately turns off the burner power supply, enters the interlocking state, sound and light alarm until the fault is eliminated, and then press the reset button to cancel the alarm state.


    3). Boiler water level over-limit protection: When the water level is higher than the upper limit warning water level, the sound and light alarm. Prompt "the water level in the pot is too high", the display prompts drainage, and the pump starts to drain. The fault is automatically restored after the fault is eliminated, and the pump stops working.

    TWO PART ASSEMBLED BOILER
    boiler modelUnitSZL6-1.25/1.6-AIISZL8-1.25/1.6-AIISZL10-1.25/1.6-AIISZL12-1.25/1.6-AIISZL15-1.25/1.6-AIISZL20-1.25/1.6-AIISZL25-1.25/1.6-AII
    capacityton/h681012152025
    rated pressureMpa12.5/1.61.25/1.61.25/1.61.25/1.61.25/1.61.25/1.61.25/1.6
    rated steam temeperature193/204193/204193/204193/204193/204193/204193/204
    feed water temperature105105105105105105105
    radiation aream218.1922.1425.825.834.11753.7899.21
    convection aream2121.9158.86200.38250.17331.616411.8457.78
    economizer aream253.13104.64130.8174.4/261.1117.72/117.2212.4476.16
    valid grate aream27.559.3410.9812.7816.2420.8424.76
    applicable fuelCOALCOALCOALCOALCOALCOALCOAL
    exhaust gas temperature165.78/169.85161/165160/162158/150156.7/159.4153/159152/156
    design efficiency%80.11/79.4479.95/79.9880.55/80.2880.68/80.7280.48/80.5681.09/80.7781.38/81.26
    fuel consumptionkg/h863.28/874.781153.42/1161.381430.96/1442.741714.5/1721.82167.89/2164.72868.63/2884.73551/3556
    max part size for deliverymm7100*2800*3500
    7300*2540*2330
    7300*3000*3500
    7400*2700*2330
    7600*3200*3500
    7700*2900*2330
    7600*3200*3500
    8500*2900*2330
    7350*3373*3505
    8904*3370*1100
    7814.7*3573*3511
    9439*3768*1100
    8478*2600*2740
    Bulk packing

    Quality Low Pressure Coal Fired Steam Boiler Wood Chip Biomass Boiler Over - Limit Protection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yong Xing Boiler Group Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)